DOI 10.15372/SSMJ20200603
Development of invasive EEG in epilepsy surgery (review)
Author Affiliations
1Novosibirsk Center of Neurosurgery of Minzdrav of Russia 630087, Novosibirsk, Nemirovicha-Danchenko str., 132/1
2Novosibirsk Center of Neurosurgery of Minzdrav of Russia 630087, Novosibirsk, Nemirovicha-Danchenko str., 132/1
Abstract
There are different diagnostic methods that used for localization of the seizure onset zone in focal refractory epilepsy cases. Invasive video-EEG recording is the «gold standard» in determining the epileptogenic zone among other diagnostic methods. Invasive EEG already has a long history of using. This article provides historical review and analysis of the techniques, their advantages and disadvantages, current issues.
Key words
References- Krylov V.V., Guekht A.B., Trifonov I.S., Lebedeva A.V., Kaimovsky I.L., Sinkin M.V., Grigorieva E.V., Grishkina M.N., Shyshkina L.V., Kochetkova O.O. Outcomes of surgical treatment of patients with pharmacoresistant epilepsy. Zhurnal nevrologii i psikhiatrii imeni Sergeya Sergeevicha Korsakova = S.S. Korsakov Journal of Neurology and Psychiatry. 2016; 116 (9): 13-18. [In Russian]. doi:10.17116/jnevro20161169213-18
- Banerjee P., Filippi D., Hauser W.A. The descriptive epidemiology of epilepsy - A review. Epilepsy Res. 2009; 85 (1): 31-45. doi:10.1016/j.eplepsyres.2009.03.003
- Jin P., Wu D., Li X., Ren L., Wang Y. Towards precision medicine in epilepsy surgery. Ann. Transl. Med. 2016; 4 (2): 24. doi: 10.3978/j.issn.2305-5839.2015.12.65
- Jayakar P., Gotman J., Harvey A., Palmini A., Tassi L., Schomer D., Dubeau F., Bartolomei F., Yu A., Kršek P., Velis D., Kahane P. Diagnostic utility of invasive EEG for epilepsy surgery: Indications, modalities, and techniques. Epilepsia. 2016; 57 (11): 1735-1747. doi: 10.1111/epi.13515
- Taussig D., Montavont A., Isnard J. Invasive EEG explorations. Neurophysiol. Clin. 2015; 45 (1): 113-119. doi:10.1016/j.neucli.2014.11.006
- Fisch B. Spehlmann's EEG Primer. Amsterdam: Elsevier, 1997. 642 p.
- Girvin J. History of epilepsy surgery. In: Operative Techniques in Epilepsy. Switzerland: Springer International Publishing, 2014. 307 p.
- Olivier A., Boling W., Tanriverdi T. History of epilepsy surgery. In: Techniques in Epilepsy Surgery. United Kingdom: Cambridge University Press, 2012. 298 p.
- Tyagun N.S., Mukhin E.Yu. Development of epilepsy surgery in the 2-nd half of XIX through mid-XX century. Russkiy zhurnal detskoy nevrologii =Russian Journal of Child Neurology. 2009; 4 (3): 41-46. [In Russian].
- Reif P., Strzelczyk A., Rosenow F. The history of invasive EEG evaluation in epilepsy patients. Seizure. 2016; 41: 191-195. doi:10.1016/j.seizure.2016.04.006
- Berger H. About the human electroencephalogram. Archiv für Psychiatrie und Nervenkrankheiten = Archives for Psychiatry and Nervous Diseases. 1929; 87: 527-570. [In German]. doi: 10.1055/s-0028-1130334
- Almeida A., Martinez V., Feindel W. The first case of invasive EEG monitoring for the surgical treatment of epilepsy: Historical significance and context. Epilepsia. 2005; 46 (7): 1082-1085. doi:10.1111/j.1528-1167.2005.66404.x
- Jasper H., Marsan C., Stoll J. Experimental studies of the subcortical projections of local cortical epileptiform discharge. Trans. Am. Neurol. Assoc. 1951; 56: 3–9.
- Lennox M., Brody B. Paroxysmal slow waves in the electro-encephalograms of patients with epilepsy and with subcortical lesions. J. Nerv. Ment. Dis. 1946; 104 (3): 237-248. doi:10.1097/00005053-194609000-00001
- Hayne R., Meyers R., Knott J. Characteristics of electrical activity of human corpus striatum and neighboring structures. J. Neurophysiol. 1949; 12 (3): 185-196. doi:10.1152/jn.1949.12.3.185
- Talairach J., Bancaud J., Bonis A., Szikla G., Tournoux P. Functional stereotaxic exploration of epilepsy. Confin. Neurol. 1962; 22 (3-5): 328-331. doi:10.1159/000104378
- Talairach J., Bancaud J. Lesion, "irritative" zone and epileptogenic focus. Confin. Neurol. 1966; 27 (1): 91-94. doi:10.1159/000103937
- Northfield D. Experiment and neurological surgery. Br. Med. J. 1968; 4 (5629): 471-477. doi:10.1136/bmj.4.5629.471
- Matias C., Sharan A., Wu C. Responsive neurostimulation for the treatment of epilepsy. Neurosurg. Clin. N. Am. 2019; 30 (2): 231-242. doi:10.1016/j.nec.2018.12.006
- Sefcik R., Opie N., John S., Kellner C., Mocco J., Oxley T. The evolution of endovascular electroencephalography: historical perspective and future applications. Neurosurg. Focus. 2016; 40 (5): E7. doi:10.3171/2016.3.focus15635
- Katz J., Abel T. Stereoelectroencephalography versus subdural electrodes for localization of the epileptogenic zone: what is the evidence? Neurotherapeutics. 2019; 16 (1): 59-66. doi: 10.1007/s13311-018-00703-2
- Zuev A.A., Golovteev A.L., Pedyash N.V., Kalybaeva N.A., Bronov O.Yu. Possibilities for surgical treatment of the pharmacoresistant form of epilepsy using robot-assisted implantation of deep electrodes for invasive stereoelectroencephalography. Neyrokhirurgiya = Neurosurgery. 2020; 22 (1): 12-20. [In Russian]. doi:10.17650/1683-3295-2020-22-1-12-20
- Podkorytova I., Hoes K., Lega B. Stereo-encephalography versus subdural electrodes for seizure localization. Neurosurg. Clin. N. Am. 2016; 27 (1): 97-109. doi:10.1016/j.nec.2015.08.008
- Minotti L., Montavont A., Scholly J., Tyvaert L., Taussig D. Indications and limits of stereoelectroencephalography (SEEG). Neurophysiol. Clin. 2018; 48 (1): 15-24. doi:10.1016/j.neucli.2017.11.006
- Cossu M., Cardinale F., Castana L., Citterio A., Francione S., Tassi L., Benabid A., Russo G. Stereoelectroencephalography in the presurgical evaluation of focal epilepsy: a retrospective analysis of 215 procedures. Neurosurgery. 2005; 57 (4): 706-718. doi:10.1227/01.neu.0000176656.33523.1e
- Serletis D., Bulacio J., Bingaman W., Najm I., González-Martínez J. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J. Neurosurg. 2014; 121 (5): 1239-1246. doi:10.3171/2014.7.jns132306
- Yang P., Zhang H., Pei J., Tian J., Lin Q., Mei Z., Zhong Z., Jia Y., Chen Z., Zheng Z. Intracranial electroencephalography with subdural and/or depth electrodes in children with epilepsy: Techniques, complications, and outcomes. Epilepsy Res. 2014; 108 (9): 1662-1670. doi:10.1016/j.eplepsyres.2014.08.011
- Vale F., Pollock G., Dionisio J., Benbadis S., Tatum W. Outcome and complications of chronically implanted subdural electrodes for the treatment of medically resistant epilepsy. Clin. Neurol. Neurosurg. 2013; 115 (7): 985-990. doi:10.1016/j.clineuro.2012.10.007
- Mullin J., Sexton D., Al-Omar S., Bingaman W., Gonzalez-Martinez J. Outcomes of subdural grid electrode monitoring in the stereoelectroencephalography era. World Neurosurg. 2016; 89: 255-258. doi:10.1016/j.wneu.2016.02.034
- Sheth S., Aronson J., Shafi M., Phillips H., Velez-Ruiz N., Walcott B., Kwon C., Mian M., Dykstra A., Cole A., Eskandar E. Utility of foramen ovale electrodes in mesial temporal lobe epilepsy. Epilepsia. 2014; 55 (5): 713-724. doi:10.1111/epi.12571
- Nilsson D., Fohlen M., Jalin C., Dorfmuller G., Bulteau C., Delalande O. Foramen ovale electrodes in the preoperative evaluation of temporal lobe epilepsy in children. Epilepsia. 2009; 50 (9): 2085-2096. doi:10.1111/j.1528-1167.2009.02135.x
- Velasco T., Sakamoto A., Alexandre V., Walz R., Dalmagro C., Bianchin M., Araújo D., Santos A., Leite J., Assirati J., Carlotti C. Foramen ovale electrodes can identify a focal seizure onset when surface eeg fails in mesial temporal lobe epilepsy. Epilepsia. 2006; 47 (8): 1300-1307. doi:10.1111/j.1528-1167.2006.00547.x
- Massot-Tarrús A., Steven D., McLachlan R., Mirsattari S., Diosy D., Parrent A., Blume W., Girvin J., Burneo J. Outcome of temporal lobe epilepsy surgery evaluated with bitemporal intracranial electrode recordings. Epilepsy Res. 2016; 127: 324-330. doi:10.1016/j.eplepsyres.2016.08.008
- Valentín A., Hernando-Quintana N., Moles-Herbera J. Jimenez-Jimenez D., Mourente S., Malik I., Selway R., Alarcón G. Depth versus subdural temporal electrodes revisited: Impact on surgical outcome after resective surgery for epilepsy. Clin. Neurophysiol. 2017; 128 (3): 418-423. doi:10.1016/j.clinph.2016.12.018
- Joswig H., Lau J., Abdallat M., Parrent A., MacDougall K., McLachlan R., Burneo J., Steven D. Stereoelectroencephalography versus subdural strip electrode implantations: feasibility, complications, and outcomes in 500 intracranial monitoring cases for drug-resistant epilepsy. Neurosurgery. 2020; 87 (1): E23-E30. doi:10.1093/neuros/nyaa112
- Yan H., Katz J., Anderson M., Mansouri A., Remick M., Ibrahim G., Abel T. Method of invasive monitoring in epilepsy surgery and seizure freedom and morbidity: A systematic review. Epilepsia. 2019; 60 (9): 1960-1972. doi:10.1111/epi.16315
- Toth M., Papp K., Gede N., Farkas K., Kovacs S., Isnard J., Hagiwara K., Gyimesi C., Kuperczko D., Doczi T., Janszky J. Surgical outcomes related to invasive EEG monitoring with subdural grids or depth electrodes in adults: A systematic review and meta-analysis. Seizure. 2019; 70: 12-19. doi:10.1016/j.seizure.2019.06.022
- Park C., Hong S. High frequency oscillations in epilepsy: detection methods and considerations in clinical application. J. Epilepsy Res. 2019; 9 (1): 1-13. doi:10.14581/jer.19001
- Jacobs J., Wu J., Perucca P., Zelmann R., Mader M., Dubeau F., Mathern G., Schulze-Bonhage A., Gotman J. Removing high-frequency oscillations. Neurology. 2018; 91 (11): e1040-e1052. doi:10.1212/wnl.0000000000006158
About Authors (Correspondence):
Dzhafarov V.M., e-mail: mvijayd@hotmail.com
Full Text
Received: 24/12/2020
Accepted: 24/12/2020